    FREECOOL-AD Adiabatic Evaporation Cooling Unit

    Top

    information

    Brief Introduction
    FREECOOL-AD, an adiabatic evaporation cooling unit, is designed for small/medium data center or electronic equipment room. Direct free cooling will be used when outdoor temperature is low; if ambient temperature rises, adiabatic mode will be used. Ambient air will blow through the built-in pad saturated with water, evaporating water by air flow.
    By using the FREECOOL-AD unit, the running hours of other air conditioning units can be highly reduced, achieving power energy saving around 30%~90%.
    The FREECOOL-AD unit using EC fan can adjust the air volume automatically according to the temperature difference with the lowest power consumption.FREECOOL-AD realizes easy installation and convenient maintenance without refrigeration system. The unit only needs to connect the inlet and outlet water pipe on the work site. Down flow and up flow units using the same structure, offering more flexibility for different customers.
    Capacity
    92000~18000m3/h  
    Applications
    Small to mid-size switching room for telecommunication
    Small to mid-size data center and computer room
    UPS and battery room
    Industrial process control center
    Features
    High energy efficiency

    Good structure design and easy maintenance

    Easy installation, choose supply air scheme flexibly
    Preventing legionnaires disease

    Supply air humidity control

    Strong structure

    Corrosion-proof

    Intelligent Control

    Random restart when power recovered

     

    Options
    G4 washable main air filter
    Electric heater
    Exhaust fan
    Gravitational pressure relief valve (air discharge)
    Electric motorized air discharge valve
    Electric motorized non-return valve
    Air inlet louver
    Mounting plinth
    RS232 communication interface card
    RS485 communication interface card
    Pcoweb card serve as web based server
    Air Conditioner Linkage Contactor (link with existing air conditioners)
    Additional room temperature sensor

     

    Model

     

    10A1

    20A2

    Power souce

     

    400V/3Ph/50Hz

    Supply air scheme

     

    UP: Up flow; DN: Down flow

    Cooling capacity(1)

    kW

    27.0

    52.8

    Free cooling capacity

    kW

    15.4

    30.2

    Supply fan

     

     

     

    Type

     

    EC Centrifugal Fan

    Qty.

    n.

    1

    2

    Air flow

    m3/h

    9200

    18000

    Water consumption(1)

    kg/h

    40.7

    79.7

    Pump

     

    DC diaphragm pump

    Width*Depth*Heigh

    mm

    1900*800*2160

    1900*1050*2460

    Weight

    mm

    400

    570

    (1)@outside air dry bulb temperature 25℃, RH30%, adiabatic cooling mode.