  1. DATACOOL-PACKAGE Packaged Precision Air Conditioner with Built-in Fresh Air Free Cooling

DATACOOL-PACKAGE Packaged Precision Air Conditioner with Built-in Fresh Air Free Cooling

Top

information

Brief Introduction
DATACOOL-PACKAGE air conditioner with built-in fresh air free cooling system is specially designed for small/medium data center and electronic equipment room. By integrating numerous advantages and latest technologies of current computer-room air conditioners, the unit can provide the values exceeding expectations for the key environment users. DATACOOL-PACKAGE is a self-contained air conditioning unit which realizes easy installation without any refrigeration piping connection.DATACOOL-PACKAGE can maximumly works in free cooling mode with the lowest power consumption, saving huge energy and lowering the operation cost.
Capacity
9.1~48.6kW  
Applications
Small to mid-size switching room for telecommunication
Small to mid-size data center and computer room
UPS and battery room
Industrial process control center
Features
Energy Saving
When the temperature difference between indoor and outdoor is higher than 10℃, the built-in free cooling system can supply 100% of the cooling capacity, saving 90% energy.


Good structure design and easy maintenance
The unit can be fully maintained from the front.
Offer two structure types: packaged and segmental structure. Packaged structure facilitates the installation. Segmental structure includes main unit and fan box. Fan box should be assembled with main unit at worksite, but it is easier for transport.


High sensible heat ratio
The Sensible heat ratio of all the units are higher than 0.9.


Wide working range(-30°C~45°C)


Corrosion-proof
The unit frame and panels are coated with the corrosion proof epoxy powder.
 

High efficiency EC fan with high torque and low leakage air damper


Fully automatic control
Equipped with a full automatic control system.automatically selects mechanic cooling or free cooling according to the temperature of indoor side and outdoor side. The controller will change the working unit automatically to balance the working time of the 2 units.

Be capable of automatic reversion to the fresh air cooling mode upon mechanical failure.


Random restart when power recovered


The attend mode function
When service people is working in base station, he can simply press 2 buttons on the controller interface, then the control temperature of the air conditioner will be set as 24℃ (settable) automatically. Half an hour later (settable) the control temperature of air conditioner will be returned to original set point.


4 levels password protection, voltage protection, alarms, providing the unit with full protection.


Automatic self-diagnosis
The unit is provided with an automatic self-diagnosis procedure and the service worker can start the check only by pressing a button.


Running data logging
If the interval of data logging is less than 5 minutes, the controller can store at least 48 hours working data.


Remote monitoring of Web server card to know the operation state of the unit and conduct the remote control.

Options
Electric heater
Capacity 4.5kW, 6kW ,and related control components.


Filter clogged alarm
Air pressure switch to send the alarm


Special Condenser
Condenser coil coated with phenolic anti-corrosion resin.


RS485
communication card with MODBUS communication protocol

 

Web server
Provide IP address for remote monitoring through internet.

 

Protocol converter
Convert the protocol from MODBUS to TCP/IP
Additional temperature sensors can be located at different places in the room


Alternative power supply
Following power source would be available:
220/1/50 208~230/1/60
380~420/3/50 208~230/3/60
460/3/60

 

Model

 

8E1A1

15E1A1

22E1A2

30E2A2

45E2A3

Supply air scheme

 

O:Up flow; U:Down flow

Power source

 

380V/3Ph/50Hz

Cooling capacity(1)

kW

9.1

16.5

23.9

33

48.6

Free cooling capacity(2)

kW

13.1

18.5

25

27.5

50

Compressor

 

Hermetic Scroll Type

Evaporator fan

 

 

 

 

 

 

Type

 

EC Centrifugal Fan

Qty. of fan

n.

1

1

1

1

2

Air volume

m3/h

4350

6150

8320

9150

16640

Condenser fan

 

 

 

 

 

 

Type

 

EC Centrifugal Fan

Qty. of fan

n.

1

1

1

2

4

Air volume

m3/h

4200

5100

5800

10200

14400

Electric heater  capacity

kW

4.5

4.5

4.5

6

9

Width*Depth*Height(packaged unit)

mm

1160*1050*2350

1460*1100*2350

2920*1100*2350

Width*Depth*Height(split unit)

mm

1160*1050*2450

1460*1100*2450

2920*1100*2450

Weight (packaged unit)

Kg

450

520

610

660

1280

Weight (split unit)

Kg

500

570

680

730

1420

(1) Return air dry bulb temperature 24℃,RH50%,Outdoor dry bulb temperature35℃;
(2) Indoor temperature and outdoor temperature difference (ΔT) is 10℃.